make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_neighh_suppress.sh TEST_GEN_PROGS="" run_tests make: Entering directory '/home/virtme/testing-1/tools/testing/selftests' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' TAP version 13 1..1 # timeout set to 3600 # selftests: net: test_bridge_neigh_suppress.sh # 6.09 [+6.09] # 6.09 [+0.00] Per-port ARP suppression - VLAN 10 # 6.09 [+0.00] ---------------------------------- # 6.18 [+0.09] TEST: arping [ OK ] # 6.30 [+0.12] TEST: ARP suppression [ OK ] # 6.32 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 6.35 [+0.03] TEST: arping [ OK ] # 6.48 [+0.12] TEST: ARP suppression [ OK ] # 6.50 [+0.03] TEST: FDB entry installation [ OK ] # 6.53 [+0.03] TEST: arping [ OK ] # 6.65 [+0.12] TEST: ARP suppression [ OK ] # 6.66 [+0.01] TEST: Neighbor entry installation [ OK ] # 6.70 [+0.03] TEST: arping [ OK ] # 6.82 [+0.12] TEST: ARP suppression [ OK ] # 6.83 [+0.01] TEST: H2 down [ OK ] # 6.87 [+0.04] TEST: arping [ OK ] # 6.99 [+0.12] TEST: ARP suppression [ OK ] # 7.00 [+0.01] TEST: H2 up [ OK ] # 7.03 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 7.06 [+0.04] TEST: arping [ OK ] # 7.18 [+0.12] TEST: ARP suppression [ OK ] # 7.20 [+0.01] TEST: H2 down [ OK ] # 8.22 [+1.03] TEST: arping [ OK ] # 8.35 [+0.13] TEST: ARP suppression [ OK ] # 8.35 [+0.00] # 8.35 [+0.00] Per-port ARP suppression - VLAN 20 # 8.35 [+0.00] ---------------------------------- # 8.41 [+0.06] TEST: arping [ OK ] # 8.53 [+0.12] TEST: ARP suppression [ OK ] # 8.55 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 8.59 [+0.04] TEST: arping [ OK ] # 8.72 [+0.12] TEST: ARP suppression [ OK ] # 8.74 [+0.02] TEST: FDB entry installation [ OK ] # 8.77 [+0.02] TEST: arping [ OK ] # 8.89 [+0.12] TEST: ARP suppression [ OK ] # 8.90 [+0.01] TEST: Neighbor entry installation [ OK ] # 8.93 [+0.03] TEST: arping [ OK ] # 9.05 [+0.12] TEST: ARP suppression [ OK ] # 9.06 [+0.01] TEST: H2 down [ OK ] # 9.10 [+0.04] TEST: arping [ OK ] # 9.22 [+0.12] TEST: ARP suppression [ OK ] # 9.24 [+0.01] TEST: H2 up [ OK ] # 9.26 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 9.29 [+0.03] TEST: arping [ OK ] # 9.42 [+0.13] TEST: ARP suppression [ OK ] # 9.43 [+0.01] TEST: H2 down [ OK ] # 10.46 [+1.03] TEST: arping [ OK ] # 10.58 [+0.12] TEST: ARP suppression [ OK ] # 16.85 [+6.27] # 16.85 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 10 # 16.85 [+0.00] ----------------------------------------------- # 16.88 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.12 [+0.25] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.24 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 17.25 [+0.00] # 17.25 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 20 # 17.25 [+0.00] ----------------------------------------------- # 17.26 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.53 [+0.27] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.65 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 23.84 [+6.19] # 23.84 [+0.00] Per-port NS suppression - VLAN 10 # 23.84 [+0.00] --------------------------------- # 23.88 [+0.05] TEST: ndisc6 [ OK ] # 24.01 [+0.12] TEST: NS suppression [ OK ] # 24.03 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 24.05 [+0.02] TEST: ndisc6 [ OK ] # 24.17 [+0.12] TEST: NS suppression [ OK ] # 24.19 [+0.02] TEST: FDB entry installation [ OK ] # 24.21 [+0.02] TEST: ndisc6 [ OK ] # 24.33 [+0.12] TEST: NS suppression [ OK ] # 24.34 [+0.01] TEST: Neighbor entry installation [ OK ] # 24.35 [+0.02] TEST: ndisc6 [ OK ] # 24.47 [+0.12] TEST: NS suppression [ OK ] # 24.49 [+0.01] TEST: H2 down [ OK ] # 24.50 [+0.02] TEST: ndisc6 [ OK ] # 24.62 [+0.12] TEST: NS suppression [ OK ] # 24.63 [+0.01] TEST: H2 up [ OK ] # 24.65 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 24.67 [+0.01] TEST: ndisc6 [ OK ] # 24.79 [+0.12] TEST: NS suppression [ OK ] # 24.80 [+0.01] TEST: H2 down [ OK ] # 29.82 [+5.02] TEST: ndisc6 [ OK ] # 29.95 [+0.12] TEST: NS suppression [ OK ] # 29.95 [+0.00] # 29.95 [+0.00] Per-port NS suppression - VLAN 20 # 29.95 [+0.00] --------------------------------- # 29.99 [+0.04] TEST: ndisc6 [ OK ] # 30.11 [+0.12] TEST: NS suppression [ OK ] # 30.13 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 30.15 [+0.02] TEST: ndisc6 [ OK ] # 30.27 [+0.12] TEST: NS suppression [ OK ] # 30.29 [+0.02] TEST: FDB entry installation [ OK ] # 30.30 [+0.01] TEST: ndisc6 [ OK ] # 30.42 [+0.12] TEST: NS suppression [ OK ] # 30.43 [+0.01] TEST: Neighbor entry installation [ OK ] # 30.45 [+0.02] TEST: ndisc6 [ OK ] # 30.57 [+0.12] TEST: NS suppression [ OK ] # 30.58 [+0.01] TEST: H2 down [ OK ] # 30.59 [+0.01] TEST: ndisc6 [ OK ] # 30.71 [+0.12] TEST: NS suppression [ OK ] # 30.72 [+0.01] TEST: H2 up [ OK ] # 30.74 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 30.76 [+0.02] TEST: ndisc6 [ OK ] # 30.88 [+0.12] TEST: NS suppression [ OK ] # 30.89 [+0.01] TEST: H2 down [ OK ] # 35.91 [+5.02] TEST: ndisc6 [ OK ] # 36.04 [+0.12] TEST: NS suppression [ OK ] # 42.26 [+6.23] # 42.26 [+0.00] Unicast NS, per-port NS suppression - VLAN 10 # 42.26 [+0.00] --------------------------------------------- # 42.28 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.54 [+0.26] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.66 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 42.66 [+0.00] # 42.66 [+0.00] Unicast NS, per-port NS suppression - VLAN 20 # 42.66 [+0.00] --------------------------------------------- # 42.68 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.96 [+0.27] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 43.08 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 49.46 [+6.38] # 49.46 [+0.00] Per-{Port, VLAN} ARP suppression # 49.46 [+0.00] -------------------------------- # 49.60 [+0.14] TEST: "neigh_vlan_suppress" is on [ OK ] # 49.64 [+0.04] TEST: arping (VLAN 10) [ OK ] # 49.67 [+0.03] TEST: arping (VLAN 20) [ OK ] # 49.79 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.92 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.94 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 49.95 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 49.98 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.01 [+0.04] TEST: arping (VLAN 20) [ OK ] # 50.13 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.25 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.27 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 50.30 [+0.02] TEST: arping (VLAN 10) [ OK ] # 50.33 [+0.04] TEST: arping (VLAN 20) [ OK ] # 50.45 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.58 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.60 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 50.63 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.67 [+0.04] TEST: arping (VLAN 20) [ OK ] # 50.79 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.91 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.93 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 50.96 [+0.03] TEST: arping (VLAN 10) [ OK ] # 51.00 [+0.04] TEST: arping (VLAN 20) [ OK ] # 51.12 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.25 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 51.27 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 51.29 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 51.33 [+0.04] TEST: arping (VLAN 10) [ OK ] # 51.37 [+0.04] TEST: arping (VLAN 20) [ OK ] # 51.49 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.62 [+0.13] TEST: ARP suppression (VLAN 20) [ OK ] # 57.93 [+6.32] # 57.93 [+0.00] Per-{Port, VLAN} NS suppression # 57.93 [+0.00] ------------------------------- # 58.09 [+0.15] TEST: "neigh_vlan_suppress" is on [ OK ] # 58.10 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.12 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.24 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.37 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.39 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 58.41 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 58.42 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.44 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.57 [+0.13] TEST: NS suppression (VLAN 10) [ OK ] # 58.69 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.71 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 58.73 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.75 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.87 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.00 [+0.13] TEST: NS suppression (VLAN 20) [ OK ] # 59.02 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 59.04 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 59.06 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.18 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.30 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.33 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 59.35 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 59.36 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.49 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.61 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.63 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 59.66 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 59.67 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 59.69 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.81 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.94 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 60.09 [+0.16] # 60.09 [+0.00] Tests passed: 160 # 60.09 [+0.00] Tests failed: 0 ok 1 selftests: net: test_bridge_neigh_suppress.sh make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests' xx__-> echo $? 0 xx__->