make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_neighh_suppress.sh TEST_GEN_PROGS="" run_tests make: Entering directory '/home/virtme/testing-1/tools/testing/selftests' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' TAP version 13 1..1 # timeout set to 3600 # selftests: net: test_bridge_neigh_suppress.sh # 5.83 [+5.83] # 5.83 [+0.00] Per-port ARP suppression - VLAN 10 # 5.83 [+0.00] ---------------------------------- # 5.92 [+0.09] TEST: arping [ OK ] # 6.04 [+0.12] TEST: ARP suppression [ OK ] # 6.06 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 6.09 [+0.03] TEST: arping [ OK ] # 6.21 [+0.12] TEST: ARP suppression [ OK ] # 6.23 [+0.02] TEST: FDB entry installation [ OK ] # 6.26 [+0.03] TEST: arping [ OK ] # 6.38 [+0.12] TEST: ARP suppression [ OK ] # 6.39 [+0.01] TEST: Neighbor entry installation [ OK ] # 6.41 [+0.02] TEST: arping [ OK ] # 6.53 [+0.12] TEST: ARP suppression [ OK ] # 6.54 [+0.01] TEST: H2 down [ OK ] # 6.56 [+0.02] TEST: arping [ OK ] # 6.68 [+0.12] TEST: ARP suppression [ OK ] # 6.69 [+0.01] TEST: H2 up [ OK ] # 6.70 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 6.72 [+0.02] TEST: arping [ OK ] # 6.84 [+0.12] TEST: ARP suppression [ OK ] # 6.85 [+0.01] TEST: H2 down [ OK ] # 7.88 [+1.02] TEST: arping [ OK ] # 8.00 [+0.12] TEST: ARP suppression [ OK ] # 8.00 [+0.00] # 8.00 [+0.00] Per-port ARP suppression - VLAN 20 # 8.00 [+0.00] ---------------------------------- # 8.05 [+0.04] TEST: arping [ OK ] # 8.16 [+0.12] TEST: ARP suppression [ OK ] # 8.18 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 8.20 [+0.03] TEST: arping [ OK ] # 8.32 [+0.12] TEST: ARP suppression [ OK ] # 8.34 [+0.02] TEST: FDB entry installation [ OK ] # 8.37 [+0.03] TEST: arping [ OK ] # 8.48 [+0.12] TEST: ARP suppression [ OK ] # 8.49 [+0.01] TEST: Neighbor entry installation [ OK ] # 8.51 [+0.02] TEST: arping [ OK ] # 8.63 [+0.12] TEST: ARP suppression [ OK ] # 8.64 [+0.01] TEST: H2 down [ OK ] # 8.67 [+0.03] TEST: arping [ OK ] # 8.79 [+0.12] TEST: ARP suppression [ OK ] # 8.80 [+0.01] TEST: H2 up [ OK ] # 8.81 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 8.84 [+0.03] TEST: arping [ OK ] # 8.96 [+0.12] TEST: ARP suppression [ OK ] # 8.97 [+0.01] TEST: H2 down [ OK ] # 10.00 [+1.02] TEST: arping [ OK ] # 10.11 [+0.12] TEST: ARP suppression [ OK ] # 16.11 [+6.00] # 16.12 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 10 # 16.12 [+0.00] ----------------------------------------------- # 16.14 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 16.36 [+0.22] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 16.48 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 16.48 [+0.00] # 16.48 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 20 # 16.48 [+0.00] ----------------------------------------------- # 16.50 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 16.73 [+0.23] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 16.85 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 22.89 [+6.04] # 22.89 [+0.00] Per-port NS suppression - VLAN 10 # 22.89 [+0.00] --------------------------------- # 22.93 [+0.04] TEST: ndisc6 [ OK ] # 23.05 [+0.12] TEST: NS suppression [ OK ] # 23.06 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 23.08 [+0.01] TEST: ndisc6 [ OK ] # 23.20 [+0.12] TEST: NS suppression [ OK ] # 23.21 [+0.02] TEST: FDB entry installation [ OK ] # 23.23 [+0.01] TEST: ndisc6 [ OK ] # 23.34 [+0.12] TEST: NS suppression [ OK ] # 23.35 [+0.01] TEST: Neighbor entry installation [ OK ] # 23.37 [+0.01] TEST: ndisc6 [ OK ] # 23.48 [+0.12] TEST: NS suppression [ OK ] # 23.49 [+0.01] TEST: H2 down [ OK ] # 23.51 [+0.01] TEST: ndisc6 [ OK ] # 23.63 [+0.12] TEST: NS suppression [ OK ] # 23.64 [+0.01] TEST: H2 up [ OK ] # 23.65 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 23.67 [+0.01] TEST: ndisc6 [ OK ] # 23.78 [+0.12] TEST: NS suppression [ OK ] # 23.79 [+0.01] TEST: H2 down [ OK ] # 28.81 [+5.02] TEST: ndisc6 [ OK ] # 28.94 [+0.12] TEST: NS suppression [ OK ] # 28.94 [+0.00] # 28.94 [+0.00] Per-port NS suppression - VLAN 20 # 28.94 [+0.00] --------------------------------- # 28.98 [+0.04] TEST: ndisc6 [ OK ] # 29.09 [+0.12] TEST: NS suppression [ OK ] # 29.12 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 29.13 [+0.01] TEST: ndisc6 [ OK ] # 29.25 [+0.12] TEST: NS suppression [ OK ] # 29.27 [+0.02] TEST: FDB entry installation [ OK ] # 29.28 [+0.01] TEST: ndisc6 [ OK ] # 29.40 [+0.12] TEST: NS suppression [ OK ] # 29.41 [+0.01] TEST: Neighbor entry installation [ OK ] # 29.43 [+0.01] TEST: ndisc6 [ OK ] # 29.55 [+0.12] TEST: NS suppression [ OK ] # 29.56 [+0.01] TEST: H2 down [ OK ] # 29.57 [+0.01] TEST: ndisc6 [ OK ] # 29.69 [+0.12] TEST: NS suppression [ OK ] # 29.70 [+0.01] TEST: H2 up [ OK ] # 29.71 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 29.73 [+0.01] TEST: ndisc6 [ OK ] # 29.85 [+0.12] TEST: NS suppression [ OK ] # 29.86 [+0.01] TEST: H2 down [ OK ] # 34.88 [+5.02] TEST: ndisc6 [ OK ] # 35.00 [+0.12] TEST: NS suppression [ OK ] # 41.25 [+6.25] # 41.25 [+0.00] Unicast NS, per-port NS suppression - VLAN 10 # 41.25 [+0.00] --------------------------------------------- # 41.28 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 41.54 [+0.27] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 41.66 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 41.67 [+0.00] # 41.67 [+0.00] Unicast NS, per-port NS suppression - VLAN 20 # 41.67 [+0.00] --------------------------------------------- # 41.69 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 41.93 [+0.24] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.05 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 48.36 [+6.31] # 48.36 [+0.00] Per-{Port, VLAN} ARP suppression # 48.36 [+0.00] -------------------------------- # 48.47 [+0.11] TEST: "neigh_vlan_suppress" is on [ OK ] # 48.49 [+0.02] TEST: arping (VLAN 10) [ OK ] # 48.52 [+0.03] TEST: arping (VLAN 20) [ OK ] # 48.64 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 48.76 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 48.78 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 48.79 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 48.82 [+0.03] TEST: arping (VLAN 10) [ OK ] # 48.84 [+0.02] TEST: arping (VLAN 20) [ OK ] # 48.96 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.08 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.10 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 49.12 [+0.02] TEST: arping (VLAN 10) [ OK ] # 49.15 [+0.02] TEST: arping (VLAN 20) [ OK ] # 49.27 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.39 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.40 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 49.44 [+0.03] TEST: arping (VLAN 10) [ OK ] # 49.47 [+0.03] TEST: arping (VLAN 20) [ OK ] # 49.59 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.71 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.73 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 49.76 [+0.02] TEST: arping (VLAN 10) [ OK ] # 49.78 [+0.02] TEST: arping (VLAN 20) [ OK ] # 49.90 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.02 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.04 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 50.06 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 50.09 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.12 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.24 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.36 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 56.51 [+6.15] # 56.51 [+0.00] Per-{Port, VLAN} NS suppression # 56.51 [+0.00] ------------------------------- # 56.64 [+0.12] TEST: "neigh_vlan_suppress" is on [ OK ] # 56.65 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 56.67 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 56.79 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 56.90 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 56.92 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 56.93 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 56.95 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 56.96 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.08 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.20 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.22 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 57.23 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.25 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 57.37 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.49 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.51 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 57.52 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.53 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.65 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.77 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.79 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 57.80 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.82 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.94 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.05 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.07 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 58.09 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 58.10 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.11 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.23 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.35 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.47 [+0.12] # 58.47 [+0.00] Tests passed: 160 # 58.47 [+0.00] Tests failed: 0 ok 1 selftests: net: test_bridge_neigh_suppress.sh make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests' xx__-> echo $? 0 xx__->