make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_neighh_suppress.sh TEST_GEN_PROGS="" run_tests make: Entering directory '/home/virtme/testing-1/tools/testing/selftests' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' TAP version 13 1..1 # timeout set to 3600 # selftests: net: test_bridge_neigh_suppress.sh # 5.98 [+5.98] # 5.98 [+0.00] Per-port ARP suppression - VLAN 10 # 5.98 [+0.00] ---------------------------------- # 6.08 [+0.10] TEST: arping [ OK ] # 6.21 [+0.12] TEST: ARP suppression [ OK ] # 6.23 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 6.25 [+0.02] TEST: arping [ OK ] # 6.37 [+0.12] TEST: ARP suppression [ OK ] # 6.39 [+0.02] TEST: FDB entry installation [ OK ] # 6.41 [+0.02] TEST: arping [ OK ] # 6.54 [+0.12] TEST: ARP suppression [ OK ] # 6.55 [+0.01] TEST: Neighbor entry installation [ OK ] # 6.58 [+0.04] TEST: arping [ OK ] # 6.70 [+0.12] TEST: ARP suppression [ OK ] # 6.71 [+0.01] TEST: H2 down [ OK ] # 6.75 [+0.03] TEST: arping [ OK ] # 6.87 [+0.12] TEST: ARP suppression [ OK ] # 6.88 [+0.01] TEST: H2 up [ OK ] # 6.90 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 6.93 [+0.03] TEST: arping [ OK ] # 7.05 [+0.12] TEST: ARP suppression [ OK ] # 7.06 [+0.01] TEST: H2 down [ OK ] # 8.09 [+1.03] TEST: arping [ OK ] # 8.21 [+0.12] TEST: ARP suppression [ OK ] # 8.21 [+0.00] # 8.21 [+0.00] Per-port ARP suppression - VLAN 20 # 8.22 [+0.00] ---------------------------------- # 8.28 [+0.07] TEST: arping [ OK ] # 8.40 [+0.12] TEST: ARP suppression [ OK ] # 8.42 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 8.46 [+0.03] TEST: arping [ OK ] # 8.58 [+0.12] TEST: ARP suppression [ OK ] # 8.60 [+0.02] TEST: FDB entry installation [ OK ] # 8.64 [+0.04] TEST: arping [ OK ] # 8.76 [+0.12] TEST: ARP suppression [ OK ] # 8.77 [+0.01] TEST: Neighbor entry installation [ OK ] # 8.81 [+0.04] TEST: arping [ OK ] # 8.94 [+0.12] TEST: ARP suppression [ OK ] # 8.95 [+0.01] TEST: H2 down [ OK ] # 8.97 [+0.03] TEST: arping [ OK ] # 9.09 [+0.12] TEST: ARP suppression [ OK ] # 9.10 [+0.01] TEST: H2 up [ OK ] # 9.13 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 9.16 [+0.03] TEST: arping [ OK ] # 9.28 [+0.12] TEST: ARP suppression [ OK ] # 9.29 [+0.01] TEST: H2 down [ OK ] # 10.32 [+1.03] TEST: arping [ OK ] # 10.44 [+0.12] TEST: ARP suppression [ OK ] # 16.71 [+6.27] # 16.71 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 10 # 16.71 [+0.00] ----------------------------------------------- # 16.73 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.00 [+0.27] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.12 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 17.12 [+0.00] # 17.12 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 20 # 17.13 [+0.00] ----------------------------------------------- # 17.14 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.40 [+0.26] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.52 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 23.77 [+6.25] # 23.77 [+0.00] Per-port NS suppression - VLAN 10 # 23.77 [+0.00] --------------------------------- # 23.82 [+0.05] TEST: ndisc6 [ OK ] # 23.94 [+0.12] TEST: NS suppression [ OK ] # 23.96 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 23.98 [+0.01] TEST: ndisc6 [ OK ] # 24.09 [+0.12] TEST: NS suppression [ OK ] # 24.12 [+0.02] TEST: FDB entry installation [ OK ] # 24.13 [+0.01] TEST: ndisc6 [ OK ] # 24.25 [+0.12] TEST: NS suppression [ OK ] # 24.26 [+0.01] TEST: Neighbor entry installation [ OK ] # 24.27 [+0.01] TEST: ndisc6 [ OK ] # 24.39 [+0.12] TEST: NS suppression [ OK ] # 24.40 [+0.01] TEST: H2 down [ OK ] # 24.42 [+0.01] TEST: ndisc6 [ OK ] # 24.54 [+0.12] TEST: NS suppression [ OK ] # 24.55 [+0.01] TEST: H2 up [ OK ] # 24.57 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 24.58 [+0.01] TEST: ndisc6 [ OK ] # 24.70 [+0.12] TEST: NS suppression [ OK ] # 24.71 [+0.01] TEST: H2 down [ OK ] # 29.73 [+5.02] TEST: ndisc6 [ OK ] # 29.85 [+0.12] TEST: NS suppression [ OK ] # 29.85 [+0.00] # 29.86 [+0.00] Per-port NS suppression - VLAN 20 # 29.86 [+0.00] --------------------------------- # 29.90 [+0.04] TEST: ndisc6 [ OK ] # 30.02 [+0.12] TEST: NS suppression [ OK ] # 30.04 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 30.06 [+0.01] TEST: ndisc6 [ OK ] # 30.18 [+0.12] TEST: NS suppression [ OK ] # 30.20 [+0.02] TEST: FDB entry installation [ OK ] # 30.22 [+0.01] TEST: ndisc6 [ OK ] # 30.34 [+0.12] TEST: NS suppression [ OK ] # 30.35 [+0.01] TEST: Neighbor entry installation [ OK ] # 30.37 [+0.02] TEST: ndisc6 [ OK ] # 30.49 [+0.12] TEST: NS suppression [ OK ] # 30.50 [+0.01] TEST: H2 down [ OK ] # 30.51 [+0.02] TEST: ndisc6 [ OK ] # 30.64 [+0.12] TEST: NS suppression [ OK ] # 30.65 [+0.01] TEST: H2 up [ OK ] # 30.67 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 30.68 [+0.01] TEST: ndisc6 [ OK ] # 30.80 [+0.12] TEST: NS suppression [ OK ] # 30.82 [+0.01] TEST: H2 down [ OK ] # 35.84 [+5.02] TEST: ndisc6 [ OK ] # 35.97 [+0.13] TEST: NS suppression [ OK ] # 42.22 [+6.25] # 42.22 [+0.00] Unicast NS, per-port NS suppression - VLAN 10 # 42.22 [+0.00] --------------------------------------------- # 42.24 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.48 [+0.24] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.60 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 42.60 [+0.00] # 42.60 [+0.00] Unicast NS, per-port NS suppression - VLAN 20 # 42.60 [+0.00] --------------------------------------------- # 42.62 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.86 [+0.24] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.98 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 49.19 [+6.21] # 49.19 [+0.00] Per-{Port, VLAN} ARP suppression # 49.19 [+0.00] -------------------------------- # 49.31 [+0.13] TEST: "neigh_vlan_suppress" is on [ OK ] # 49.35 [+0.04] TEST: arping (VLAN 10) [ OK ] # 49.39 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.51 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.63 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.65 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 49.67 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 49.70 [+0.03] TEST: arping (VLAN 10) [ OK ] # 49.74 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.86 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.98 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.00 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 50.04 [+0.04] TEST: arping (VLAN 10) [ OK ] # 50.07 [+0.02] TEST: arping (VLAN 20) [ OK ] # 50.19 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.31 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.33 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 50.36 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.40 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.52 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.64 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.66 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 50.69 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.71 [+0.02] TEST: arping (VLAN 20) [ OK ] # 50.83 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.95 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.97 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 50.99 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 51.02 [+0.03] TEST: arping (VLAN 10) [ OK ] # 51.05 [+0.03] TEST: arping (VLAN 20) [ OK ] # 51.17 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.29 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 57.47 [+6.17] # 57.47 [+0.00] Per-{Port, VLAN} NS suppression # 57.47 [+0.00] ------------------------------- # 57.59 [+0.12] TEST: "neigh_vlan_suppress" is on [ OK ] # 57.60 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.62 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.74 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.86 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.88 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 57.89 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 57.90 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.92 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.04 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.16 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.18 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 58.19 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.20 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.32 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.44 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.46 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 58.48 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.49 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.61 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.73 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.75 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 58.77 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.78 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.90 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.02 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.04 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 59.06 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 59.07 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 59.09 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.21 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.33 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.46 [+0.13] # 59.46 [+0.00] Tests passed: 160 # 59.46 [+0.00] Tests failed: 0 ok 1 selftests: net: test_bridge_neigh_suppress.sh make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests' xx__-> echo $? 0 xx__->