make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_neighh_suppress.sh TEST_GEN_PROGS="" run_tests make: Entering directory '/home/virtme/testing-1/tools/testing/selftests' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' TAP version 13 1..1 # timeout set to 3600 # selftests: net: test_bridge_neigh_suppress.sh # 6.00 [+6.00] # 6.00 [+0.00] Per-port ARP suppression - VLAN 10 # 6.00 [+0.00] ---------------------------------- # 6.09 [+0.09] TEST: arping [ OK ] # 6.21 [+0.12] TEST: ARP suppression [ OK ] # 6.23 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 6.26 [+0.03] TEST: arping [ OK ] # 6.38 [+0.12] TEST: ARP suppression [ OK ] # 6.40 [+0.02] TEST: FDB entry installation [ OK ] # 6.43 [+0.03] TEST: arping [ OK ] # 6.56 [+0.12] TEST: ARP suppression [ OK ] # 6.57 [+0.01] TEST: Neighbor entry installation [ OK ] # 6.60 [+0.03] TEST: arping [ OK ] # 6.72 [+0.12] TEST: ARP suppression [ OK ] # 6.73 [+0.01] TEST: H2 down [ OK ] # 6.75 [+0.02] TEST: arping [ OK ] # 6.87 [+0.12] TEST: ARP suppression [ OK ] # 6.88 [+0.01] TEST: H2 up [ OK ] # 6.90 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 6.94 [+0.04] TEST: arping [ OK ] # 7.06 [+0.12] TEST: ARP suppression [ OK ] # 7.08 [+0.01] TEST: H2 down [ OK ] # 8.10 [+1.03] TEST: arping [ OK ] # 8.22 [+0.12] TEST: ARP suppression [ OK ] # 8.23 [+0.00] # 8.23 [+0.00] Per-port ARP suppression - VLAN 20 # 8.23 [+0.00] ---------------------------------- # 8.28 [+0.05] TEST: arping [ OK ] # 8.40 [+0.12] TEST: ARP suppression [ OK ] # 8.42 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 8.44 [+0.02] TEST: arping [ OK ] # 8.56 [+0.12] TEST: ARP suppression [ OK ] # 8.58 [+0.02] TEST: FDB entry installation [ OK ] # 8.62 [+0.04] TEST: arping [ OK ] # 8.74 [+0.12] TEST: ARP suppression [ OK ] # 8.75 [+0.01] TEST: Neighbor entry installation [ OK ] # 8.78 [+0.03] TEST: arping [ OK ] # 8.91 [+0.12] TEST: ARP suppression [ OK ] # 8.92 [+0.01] TEST: H2 down [ OK ] # 8.95 [+0.03] TEST: arping [ OK ] # 9.07 [+0.12] TEST: ARP suppression [ OK ] # 9.08 [+0.01] TEST: H2 up [ OK ] # 9.10 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 9.13 [+0.03] TEST: arping [ OK ] # 9.26 [+0.12] TEST: ARP suppression [ OK ] # 9.27 [+0.01] TEST: H2 down [ OK ] # 10.30 [+1.03] TEST: arping [ OK ] # 10.43 [+0.13] TEST: ARP suppression [ OK ] # 16.68 [+6.25] # 16.68 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 10 # 16.68 [+0.00] ----------------------------------------------- # 16.70 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 16.96 [+0.25] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.08 [+0.13] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 17.08 [+0.00] # 17.09 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 20 # 17.09 [+0.00] ----------------------------------------------- # 17.11 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.38 [+0.27] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.50 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 23.72 [+6.22] # 23.72 [+0.00] Per-port NS suppression - VLAN 10 # 23.72 [+0.00] --------------------------------- # 23.77 [+0.05] TEST: ndisc6 [ OK ] # 23.89 [+0.12] TEST: NS suppression [ OK ] # 23.92 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 23.93 [+0.02] TEST: ndisc6 [ OK ] # 24.06 [+0.12] TEST: NS suppression [ OK ] # 24.08 [+0.02] TEST: FDB entry installation [ OK ] # 24.10 [+0.02] TEST: ndisc6 [ OK ] # 24.22 [+0.12] TEST: NS suppression [ OK ] # 24.23 [+0.01] TEST: Neighbor entry installation [ OK ] # 24.25 [+0.02] TEST: ndisc6 [ OK ] # 24.37 [+0.12] TEST: NS suppression [ OK ] # 24.39 [+0.01] TEST: H2 down [ OK ] # 24.40 [+0.02] TEST: ndisc6 [ OK ] # 24.53 [+0.12] TEST: NS suppression [ OK ] # 24.54 [+0.01] TEST: H2 up [ OK ] # 24.56 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 24.58 [+0.02] TEST: ndisc6 [ OK ] # 24.70 [+0.13] TEST: NS suppression [ OK ] # 24.71 [+0.01] TEST: H2 down [ OK ] # 29.74 [+5.03] TEST: ndisc6 [ OK ] # 29.86 [+0.12] TEST: NS suppression [ OK ] # 29.86 [+0.00] # 29.86 [+0.00] Per-port NS suppression - VLAN 20 # 29.86 [+0.00] --------------------------------- # 29.91 [+0.05] TEST: ndisc6 [ OK ] # 30.03 [+0.12] TEST: NS suppression [ OK ] # 30.06 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 30.07 [+0.02] TEST: ndisc6 [ OK ] # 30.20 [+0.12] TEST: NS suppression [ OK ] # 30.22 [+0.02] TEST: FDB entry installation [ OK ] # 30.24 [+0.02] TEST: ndisc6 [ OK ] # 30.36 [+0.12] TEST: NS suppression [ OK ] # 30.37 [+0.01] TEST: Neighbor entry installation [ OK ] # 30.39 [+0.02] TEST: ndisc6 [ OK ] # 30.50 [+0.12] TEST: NS suppression [ OK ] # 30.52 [+0.01] TEST: H2 down [ OK ] # 30.53 [+0.01] TEST: ndisc6 [ OK ] # 30.65 [+0.12] TEST: NS suppression [ OK ] # 30.66 [+0.01] TEST: H2 up [ OK ] # 30.69 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 30.70 [+0.02] TEST: ndisc6 [ OK ] # 30.82 [+0.12] TEST: NS suppression [ OK ] # 30.84 [+0.01] TEST: H2 down [ OK ] # 35.86 [+5.02] TEST: ndisc6 [ OK ] # 35.98 [+0.12] TEST: NS suppression [ OK ] # 42.22 [+6.24] # 42.23 [+0.00] Unicast NS, per-port NS suppression - VLAN 10 # 42.23 [+0.00] --------------------------------------------- # 42.25 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.52 [+0.27] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.64 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 42.64 [+0.00] # 42.64 [+0.00] Unicast NS, per-port NS suppression - VLAN 20 # 42.64 [+0.00] --------------------------------------------- # 42.66 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.92 [+0.27] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 43.05 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 49.29 [+6.24] # 49.29 [+0.00] Per-{Port, VLAN} ARP suppression # 49.29 [+0.00] -------------------------------- # 49.42 [+0.13] TEST: "neigh_vlan_suppress" is on [ OK ] # 49.44 [+0.02] TEST: arping (VLAN 10) [ OK ] # 49.48 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.60 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.73 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.75 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 49.76 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 49.79 [+0.03] TEST: arping (VLAN 10) [ OK ] # 49.83 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.95 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.07 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.10 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 50.13 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.16 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.28 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.41 [+0.13] TEST: ARP suppression (VLAN 20) [ OK ] # 50.43 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 50.46 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.50 [+0.04] TEST: arping (VLAN 20) [ OK ] # 50.62 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.74 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.76 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 50.80 [+0.04] TEST: arping (VLAN 10) [ OK ] # 50.83 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.95 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.07 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 51.09 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 51.11 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 51.14 [+0.02] TEST: arping (VLAN 10) [ OK ] # 51.17 [+0.04] TEST: arping (VLAN 20) [ OK ] # 51.29 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.42 [+0.13] TEST: ARP suppression (VLAN 20) [ OK ] # 57.54 [+6.12] # 57.54 [+0.00] Per-{Port, VLAN} NS suppression # 57.54 [+0.00] ------------------------------- # 57.67 [+0.13] TEST: "neigh_vlan_suppress" is on [ OK ] # 57.69 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 57.70 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 57.82 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.94 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.96 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 57.97 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 57.99 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.00 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.12 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.24 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.26 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 58.27 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.29 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.41 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.53 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.55 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 58.57 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.58 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.70 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.82 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.84 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 58.86 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.87 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.00 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.12 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.14 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 59.16 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 59.18 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 59.19 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 59.31 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.44 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.57 [+0.13] # 59.57 [+0.00] Tests passed: 160 # 59.57 [+0.00] Tests failed: 0 ok 1 selftests: net: test_bridge_neigh_suppress.sh make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests' xx__-> echo $? 0 xx__->