make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_neighh_suppress.sh TEST_GEN_PROGS="" run_tests make: Entering directory '/home/virtme/testing-1/tools/testing/selftests' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Nothing to be done for 'all'. make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net/lib' make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net' TAP version 13 1..1 # timeout set to 3600 # selftests: net: test_bridge_neigh_suppress.sh # 6.03 [+6.03] # 6.03 [+0.00] Per-port ARP suppression - VLAN 10 # 6.03 [+0.00] ---------------------------------- # 6.12 [+0.09] TEST: arping [ OK ] # 6.24 [+0.12] TEST: ARP suppression [ OK ] # 6.26 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 6.29 [+0.03] TEST: arping [ OK ] # 6.41 [+0.12] TEST: ARP suppression [ OK ] # 6.44 [+0.02] TEST: FDB entry installation [ OK ] # 6.46 [+0.03] TEST: arping [ OK ] # 6.58 [+0.12] TEST: ARP suppression [ OK ] # 6.60 [+0.01] TEST: Neighbor entry installation [ OK ] # 6.63 [+0.03] TEST: arping [ OK ] # 6.75 [+0.12] TEST: ARP suppression [ OK ] # 6.76 [+0.01] TEST: H2 down [ OK ] # 6.78 [+0.03] TEST: arping [ OK ] # 6.90 [+0.12] TEST: ARP suppression [ OK ] # 6.91 [+0.01] TEST: H2 up [ OK ] # 6.93 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 6.96 [+0.02] TEST: arping [ OK ] # 7.08 [+0.12] TEST: ARP suppression [ OK ] # 7.09 [+0.01] TEST: H2 down [ OK ] # 8.12 [+1.03] TEST: arping [ OK ] # 8.24 [+0.12] TEST: ARP suppression [ OK ] # 8.25 [+0.00] # 8.25 [+0.00] Per-port ARP suppression - VLAN 20 # 8.25 [+0.00] ---------------------------------- # 8.30 [+0.05] TEST: arping [ OK ] # 8.42 [+0.12] TEST: ARP suppression [ OK ] # 8.44 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 8.48 [+0.03] TEST: arping [ OK ] # 8.60 [+0.12] TEST: ARP suppression [ OK ] # 8.62 [+0.02] TEST: FDB entry installation [ OK ] # 8.65 [+0.02] TEST: arping [ OK ] # 8.77 [+0.12] TEST: ARP suppression [ OK ] # 8.78 [+0.01] TEST: Neighbor entry installation [ OK ] # 8.81 [+0.03] TEST: arping [ OK ] # 8.93 [+0.12] TEST: ARP suppression [ OK ] # 8.94 [+0.01] TEST: H2 down [ OK ] # 8.98 [+0.04] TEST: arping [ OK ] # 9.10 [+0.12] TEST: ARP suppression [ OK ] # 9.11 [+0.01] TEST: H2 up [ OK ] # 9.14 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 9.17 [+0.04] TEST: arping [ OK ] # 9.30 [+0.13] TEST: ARP suppression [ OK ] # 9.31 [+0.01] TEST: H2 down [ OK ] # 10.34 [+1.03] TEST: arping [ OK ] # 10.46 [+0.12] TEST: ARP suppression [ OK ] # 16.74 [+6.28] # 16.74 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 10 # 16.75 [+0.00] ----------------------------------------------- # 16.77 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.03 [+0.26] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.15 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 17.15 [+0.00] # 17.16 [+0.00] Unicast ARP, per-port ARP suppression - VLAN 20 # 17.16 [+0.00] ----------------------------------------------- # 17.17 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 17.43 [+0.25] TEST: Unicast ARP, suppression on, h1 filter [ OK ] # 17.55 [+0.12] TEST: Unicast ARP, suppression on, h2 filter [ OK ] # 23.81 [+6.27] # 23.81 [+0.00] Per-port NS suppression - VLAN 10 # 23.81 [+0.00] --------------------------------- # 23.87 [+0.05] TEST: ndisc6 [ OK ] # 23.99 [+0.12] TEST: NS suppression [ OK ] # 24.01 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 24.03 [+0.02] TEST: ndisc6 [ OK ] # 24.15 [+0.12] TEST: NS suppression [ OK ] # 24.18 [+0.03] TEST: FDB entry installation [ OK ] # 24.19 [+0.02] TEST: ndisc6 [ OK ] # 24.31 [+0.12] TEST: NS suppression [ OK ] # 24.32 [+0.01] TEST: Neighbor entry installation [ OK ] # 24.34 [+0.02] TEST: ndisc6 [ OK ] # 24.46 [+0.12] TEST: NS suppression [ OK ] # 24.47 [+0.01] TEST: H2 down [ OK ] # 24.49 [+0.02] TEST: ndisc6 [ OK ] # 24.61 [+0.12] TEST: NS suppression [ OK ] # 24.62 [+0.01] TEST: H2 up [ OK ] # 24.65 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 24.66 [+0.02] TEST: ndisc6 [ OK ] # 24.79 [+0.12] TEST: NS suppression [ OK ] # 24.80 [+0.01] TEST: H2 down [ OK ] # 29.82 [+5.02] TEST: ndisc6 [ OK ] # 29.94 [+0.12] TEST: NS suppression [ OK ] # 29.94 [+0.00] # 29.95 [+0.00] Per-port NS suppression - VLAN 20 # 29.95 [+0.00] --------------------------------- # 29.98 [+0.03] TEST: ndisc6 [ OK ] # 30.10 [+0.12] TEST: NS suppression [ OK ] # 30.12 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 30.13 [+0.01] TEST: ndisc6 [ OK ] # 30.25 [+0.12] TEST: NS suppression [ OK ] # 30.27 [+0.02] TEST: FDB entry installation [ OK ] # 30.28 [+0.01] TEST: ndisc6 [ OK ] # 30.40 [+0.12] TEST: NS suppression [ OK ] # 30.41 [+0.01] TEST: Neighbor entry installation [ OK ] # 30.42 [+0.01] TEST: ndisc6 [ OK ] # 30.54 [+0.12] TEST: NS suppression [ OK ] # 30.55 [+0.01] TEST: H2 down [ OK ] # 30.56 [+0.01] TEST: ndisc6 [ OK ] # 30.68 [+0.12] TEST: NS suppression [ OK ] # 30.69 [+0.01] TEST: H2 up [ OK ] # 30.71 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 30.72 [+0.01] TEST: ndisc6 [ OK ] # 30.84 [+0.12] TEST: NS suppression [ OK ] # 30.85 [+0.01] TEST: H2 down [ OK ] # 35.87 [+5.02] TEST: ndisc6 [ OK ] # 35.99 [+0.12] TEST: NS suppression [ OK ] # 42.07 [+6.08] # 42.07 [+0.00] Unicast NS, per-port NS suppression - VLAN 10 # 42.07 [+0.00] --------------------------------------------- # 42.09 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.34 [+0.25] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.46 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 42.46 [+0.00] # 42.46 [+0.00] Unicast NS, per-port NS suppression - VLAN 20 # 42.46 [+0.00] --------------------------------------------- # 42.48 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 42.73 [+0.25] TEST: Unicast NS, suppression on, h1 filter [ OK ] # 42.85 [+0.12] TEST: Unicast NS, suppression on, h2 filter [ OK ] # 48.92 [+6.07] # 48.92 [+0.00] Per-{Port, VLAN} ARP suppression # 48.92 [+0.00] -------------------------------- # 49.04 [+0.11] TEST: "neigh_vlan_suppress" is on [ OK ] # 49.06 [+0.02] TEST: arping (VLAN 10) [ OK ] # 49.10 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.22 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.33 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.36 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 49.37 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 49.40 [+0.04] TEST: arping (VLAN 10) [ OK ] # 49.44 [+0.04] TEST: arping (VLAN 20) [ OK ] # 49.56 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 49.68 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 49.70 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 49.73 [+0.03] TEST: arping (VLAN 10) [ OK ] # 49.76 [+0.03] TEST: arping (VLAN 20) [ OK ] # 49.88 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.00 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.02 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 50.06 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.08 [+0.02] TEST: arping (VLAN 20) [ OK ] # 50.20 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 50.33 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.35 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 50.39 [+0.04] TEST: arping (VLAN 10) [ OK ] # 50.42 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.55 [+0.13] TEST: ARP suppression (VLAN 10) [ OK ] # 50.67 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 50.69 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 50.71 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 50.74 [+0.03] TEST: arping (VLAN 10) [ OK ] # 50.76 [+0.03] TEST: arping (VLAN 20) [ OK ] # 50.89 [+0.12] TEST: ARP suppression (VLAN 10) [ OK ] # 51.01 [+0.12] TEST: ARP suppression (VLAN 20) [ OK ] # 57.20 [+6.19] # 57.20 [+0.00] Per-{Port, VLAN} NS suppression # 57.20 [+0.00] ------------------------------- # 57.32 [+0.12] TEST: "neigh_vlan_suppress" is on [ OK ] # 57.33 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.35 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.46 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.58 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.60 [+0.02] TEST: "neigh_suppress" is on (VLAN 10) [ OK ] # 57.61 [+0.01] TEST: "neigh_suppress" is off (VLAN 20) [ OK ] # 57.62 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.64 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 57.75 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 57.87 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 57.89 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 57.90 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 57.92 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.04 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.15 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.17 [+0.02] TEST: "neigh_suppress" is off [ OK ] # 58.19 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.20 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.32 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.44 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.46 [+0.02] TEST: "neigh_suppress" is off (VLAN 10) [ OK ] # 58.48 [+0.02] TEST: ndisc6 (VLAN 10) [ OK ] # 58.49 [+0.01] TEST: ndisc6 (VLAN 20) [ OK ] # 58.61 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 58.73 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 58.75 [+0.02] TEST: "neigh_vlan_suppress" is off [ OK ] # 58.77 [+0.02] TEST: "neigh_suppress" is on [ OK ] # 58.78 [+0.01] TEST: ndisc6 (VLAN 10) [ OK ] # 58.80 [+0.02] TEST: ndisc6 (VLAN 20) [ OK ] # 58.92 [+0.12] TEST: NS suppression (VLAN 10) [ OK ] # 59.03 [+0.12] TEST: NS suppression (VLAN 20) [ OK ] # 59.16 [+0.13] # 59.16 [+0.00] Tests passed: 160 # 59.16 [+0.00] Tests failed: 0 ok 1 selftests: net: test_bridge_neigh_suppress.sh make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net' make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests' xx__-> echo $? 0 xx__->