make -C tools/testing/selftests TARGETS="net" TEST_PROGS=test_bridge_backuup_port.sh TEST_GEN_PROGS="" run_tests
make: Entering directory '/home/virtme/testing-1/tools/testing/selftests'
make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net'
make[1]: Nothing to be done for 'all'.
make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net'
make[1]: Entering directory '/home/virtme/testing-1/tools/testing/selftests/net'
TAP version 13
1..1
# timeout set to 3600
# selftests: net: test_bridge_backup_port.sh
# 5.48 [+5.48] 
# 5.48 [+0.00] Backup port
# 5.48 [+0.00] -----------
# 5.70 [+0.22] TEST: Forwarding out of swp1                                        [ OK ]
# 5.82 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 5.85 [+0.03] TEST: swp1 carrier off                                              [ OK ]
# 6.01 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 6.13 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 6.16 [+0.03] TEST: swp1 carrier on                                               [ OK ]
# 6.17 [+0.02] TEST: vx0 configured as backup port of swp1                         [ OK ]
# 6.34 [+0.17] TEST: Forwarding out of swp1                                        [ OK ]
# 6.46 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 6.85 [+0.39] TEST: swp1 carrier off                                              [ OK ]
# 7.02 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 7.14 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 7.17 [+0.03] TEST: swp1 carrier on                                               [ OK ]
# 7.34 [+0.17] TEST: Forwarding out of swp1                                        [ OK ]
# 7.45 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 7.47 [+0.02] TEST: vx0 not configured as backup port of swp1                     [ OK ]
# 7.63 [+0.15] TEST: Forwarding out of swp1                                        [ OK ]
# 7.75 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 7.86 [+0.11] TEST: swp1 carrier off                                              [ OK ]
# 8.01 [+0.15] TEST: No forwarding out of swp1                                     [ OK ]
# 8.13 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 13.71 [+5.58] 
# 13.71 [+0.00] Backup nexthop ID
# 13.71 [+0.00] -----------------
# 13.92 [+0.21] TEST: vx0 configured as backup port of swp1                         [ OK ]
# 14.10 [+0.18] TEST: Forwarding out of swp1                                        [ OK ]
# 14.22 [+0.13] TEST: No forwarding out of vx0                                      [ OK ]
# 14.25 [+0.03] TEST: swp1 carrier off                                              [ OK ]
# 14.43 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 14.55 [+0.13] TEST: Forwarding out of vx0                                         [ OK ]
# 14.68 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 14.80 [+0.12] TEST: Forwarding using VXLAN FDB entry                              [ OK ]
# 14.83 [+0.03] TEST: swp1 carrier on                                               [ OK ]
# 14.86 [+0.03] TEST: nexthop ID 10 configured as backup nexthop ID of swp1         [ OK ]
# 15.04 [+0.18] TEST: Forwarding out of swp1                                        [ OK ]
# 15.16 [+0.13] TEST: No forwarding out of vx0                                      [ OK ]
# 15.25 [+0.08] TEST: swp1 carrier off                                              [ OK ]
# 15.43 [+0.18] TEST: No forwarding out of swp1                                     [ OK ]
# 15.55 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 15.67 [+0.12] TEST: Forwarding using backup nexthop ID                            [ OK ]
# 15.79 [+0.12] TEST: No forwarding using VXLAN FDB entry                           [ OK ]
# 15.82 [+0.03] TEST: swp1 carrier on                                               [ OK ]
# 16.00 [+0.17] TEST: Forwarding out of swp1                                        [ OK ]
# 16.12 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 16.25 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 16.37 [+0.12] TEST: No forwarding using VXLAN FDB entry                           [ OK ]
# 16.39 [+0.02] TEST: No backup nexthop ID configured for swp1                      [ OK ]
# 16.57 [+0.18] TEST: Forwarding out of swp1                                        [ OK ]
# 16.69 [+0.12] TEST: No forwarding out of vx0                                      [ OK ]
# 16.82 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 16.94 [+0.12] TEST: No forwarding using VXLAN FDB entry                           [ OK ]
# 16.96 [+0.03] TEST: swp1 carrier off                                              [ OK ]
# 17.13 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 17.25 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 17.37 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 17.49 [+0.12] TEST: Forwarding using VXLAN FDB entry                              [ OK ]
# 23.09 [+5.59] 
# 23.09 [+0.00] Backup nexthop ID - invalid IDs
# 23.09 [+0.00] -------------------------------
# 23.29 [+0.20] TEST: vx0 configured as backup port of swp1                         [ OK ]
# 23.31 [+0.02] TEST: Valid nexthop as backup nexthop                               [ OK ]
# 23.34 [+0.03] TEST: swp1 carrier off                                              [ OK ]
# 23.51 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 23.63 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 23.75 [+0.12] TEST: Forwarding using backup nexthop ID                            [ OK ]
# 23.77 [+0.01] TEST: No Tx drop increase                                           [ OK ]
# 23.79 [+0.02] TEST: Non-existent nexthop as backup nexthop                        [ OK ]
# 23.94 [+0.16] TEST: No forwarding out of swp1                                     [ OK ]
# 24.06 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 24.19 [+0.13] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 24.20 [+0.01] TEST: Tx drop increased                                             [ OK ]
# 24.24 [+0.03] TEST: Blackhole nexthop as backup nexthop                           [ OK ]
# 24.41 [+0.18] TEST: No forwarding out of swp1                                     [ OK ]
# 24.53 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 24.65 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 24.67 [+0.01] TEST: Tx drop increased                                             [ OK ]
# 24.69 [+0.02] TEST: Non-group FDB nexthop as backup nexthop                       [ OK ]
# 24.85 [+0.17] TEST: No forwarding out of swp1                                     [ OK ]
# 24.98 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 25.10 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 25.11 [+0.01] TEST: Tx drop increased                                             [ OK ]
# 25.17 [+0.06] TEST: IPv6 address family nexthop as backup nexthop                 [ OK ]
# 25.35 [+0.18] TEST: No forwarding out of swp1                                     [ OK ]
# 25.47 [+0.12] TEST: Forwarding out of vx0                                         [ OK ]
# 25.60 [+0.12] TEST: No forwarding using backup nexthop ID                         [ OK ]
# 25.61 [+0.02] TEST: Tx drop increased                                             [ OK ]
# 31.24 [+5.63] 
# 31.24 [+0.00] Backup nexthop ID - ping
# 31.24 [+0.00] ------------------------
# 33.41 [+2.17] TEST: Ping with backup nexthop ID                                   [ OK ]
# 38.46 [+5.05] TEST: Ping after disabling backup nexthop ID                        [ OK ]
# 44.08 [+5.62] 
# 44.08 [+0.00] Backup nexthop ID - torture test
# 44.08 [+0.00] --------------------------------
# 74.18 [+30.10] TEST: Torture test                                                  [ OK ]
# 74.26 [+0.08] 
# 74.26 [+0.00] Tests passed:  83
# 74.26 [+0.00] Tests failed:   0
ok 1 selftests: net: test_bridge_backup_port.sh
make[1]: Leaving directory '/home/virtme/testing-1/tools/testing/selftests/net'
make: Leaving directory '/home/virtme/testing-1/tools/testing/selftests'
xx__-> echo $?
0
xx__->